Benefits of Investigating the Thermal Component for Moisture Safety in Ventilated Attics
Cold ventilated attics often have mould problems in Sweden. This is valid both for old and sometimes newly built attics. Increased insulation on the attic floor is assumed to increase the problem. To investigate this, numerical 1D models like WUFI or WUFI+ are typically used. These models give results but the physical processes are not so transparent for the user due to the complex numerical techn
